Specifications | ||
Nominal voltage | 12V | |
Rated Capacity(10 hour rate) | 100Ah | |
Dimensions | Total Height | 233+2mm(9.17 inches) |
(With terminals) | ||
Height | 208+2mm(8.19 inches) | |
Length | 406+1 mm(15.98 inches) | |
Width | 174+1 mm(6.85 inches) | |
Weight | Approx, 30.5kg(67.2lbs) |
Characteristics | ||||
Capacity* 25°C(77 °F) | 20 hour rate(5.3A) 10 hour rate(10A) 5 hour rate(18A) 3 hour rate(26.7A) 1 hour rate(65A) | 105Ah 100Ah 90Ah 80Ah 65Ah | ||
15 minute Rate(180A) | 45Ah | |||
Internal Resistance | Full charged Battery 25°C(77 °F) | Approx:6.5mQ | ||
Capacity affected by Temperature (20 hour rate) | 40°C(104 °F) 25°C(77°F) 0°C(32°F) -15°C(5°F) | 102% 100% 85% 65% | ||
Self-Discharge 25°C(77 °F) | Capacity after 3month storage Capacity after 6month storage Capacity after 12month storage | 91% 82% 64% | ||
Max,Discharge Current25°C(77 °F) | 600A(5S) | |||
Terminal | Standard | T19 | ||
Charge (Constant Voltage) | Cycle | Initial Charging Current:Less than 25A Voltage:14.4-15.0V25°C(77 °F) | ||
Float | Voltage:13.5-13.8V25t(77 V) |
Assembly
Certifications
Packing
Protect The Battery
**Do not deliberately ensure that each discharge is completed before recharging
**For a period of time (about two months is recommended), a deep charge and discharge under the control of the protection circuit can be done to modify the battery power statistics
**Long-term unused batteries should be stored in a cool place to reduce the rate of internal purification reaction
**The protection circuit is also incapable of monitoring the self-discharge of the battery. A long-term unused battery should be charged with a certain amount of electricity to prevent the battery from self-discharging in storage and causing over-discharge
**Can't be dismantled, can't be impacted / squeezed by gravity
**Prohibited to use in humid and watery places; Prohibited to use in high temperature places
Delivery & Payment Terms
**Prohibited to use in humid and watery places; Prohibited to use in high temperature places
Delivery & Payment Terms
Payment Terms | T/T | EXW | 30% in advance for deposit payment, the balance payments will be paid before shipment. |
FOB | |||
CFR/C&F | 30% in advance for deposit payment, the balance will be paid against copy of B/L | ||
CIF | |||
L/C | Optional for the amount of above 50,000 usd, L/C at sight is acceptable. | ||
West Union | Optional for amount of order less than 5000 usd | ||
Paypal | |||
Delivery Time | 7-25 days after receiving the payment or the deposit payment |